Vortex Flowmeter

Vortex Flowmeter

AUTOMAC Vortex flow meter is one kind of velocity type flow meter, its based on Karman vortex theory and adopts piezoelectric crystal

to detect the burble frequency of the fluid caused by flowing through the triangular prism in the pipeline and then measure

the flow of fluid. It is widely used in petrol, chemical industry, light industry and power heat supply and so on.

Working Principle

When the fluid in the pipeline passes the burble generator(triangular prism),burble will generate due to the acceleration of

partial flow rate. The burble will arise alternatively in two burble lines, which is called Karman vortex.

The releasing frequency of Karman vortex depends on the size of triangle prim and flow rate of fluid, while independent of

the medium feature parameter, such as the temperature, pressure, it can be indicated by the following formulas:

F=SR*v (1-1.27*d/D) Q=3600*F/K M=Q*P

F..... The releasing frequency of Karman vortex (Hz)

Sr...Strouhal number (unit: dimensionless)

V..... Medium flow rate (m/s)

d..... The width of triangle prim

D..... Vortex meter inner diameter (m)

Q...... Instantaneous volume flow rate (m3/h)

K......Vortex meter coefficient (unit pulse number/m3)

M.... Instantaneous quality flow rate (kg/h)

Flow direction

Burble generator

Burble

P..... Fluid density (kg/m3)

Benefit

  • Integrated pressure and temperature compensation.
  • 4-20mA, pulse with HART; Optional pulse with RS485
  • Wide temperature range up to highest temperature 350C
  • Adopt Japan OVAL technology and design
  • Embedded sensor, 4 piezo-electric crystal encapsulated inside the sensor.
  • No moving parts, no abrasion, non-wearing parts inside, fully welded SS304 body (Optional SS316)

Standard Specification

Size: DN15-DN300mm

Relative Humidity: 85%

Accuracy : 1.5% (standard), 1.0% (optional)

Explosion-proof: Exia IIC T6 Gb

Power Supply: 12VDC, 24VDC

Communication: RS485/Modbus, Hart, Profitbus

Flange Standard : EN1092-1PN10,PN16,PN25,PN40, ANSI BS16.5 Class 150,300,600, JIS2220 10K, 20K,40, AS2129 Table D,Table E

AS4087 PN16,PN21,PN35

Straight Pipe: Inlet Path 12D,Outlet Path 5D

Signal Output: 4-20 mA,pulse

Frequency Output: 2-3000 Hz

Ambient Temperature: -40C-55C (Non Ex-proof Place),-20C-55C (Non Ex-proof Place)

Nominal Pressure:1.6 MPa, 2.5 MPa, 4.0 MPa

Protection Grade: IP65

Velocity: 0.4-7.0 m/s liquid, 4.0-60 m/s gas, 5.070 m/s steam

Body Material: SS304(Standard), SS316(Optional)

Resistance Coefficient: Cd <2.6

Oscillatory Acceleration: 0.2g

Reynolds Number : 2x104-7x106



Reliable Flow Measurement Across Multiple Media

The vortex flowmeter delivers accurate readings for air, gas, and liquid applications, making it suitable for diverse process industries. Its capacity for precise measurement along with ATEX-certified safety ensures dependable monitoring, even in hazardous zones. With a broad size range and durable flange end connection, installation is straightforward and customizable to your system requirements.


Designed for Safety and Durability

With classification ratings of IIA, IIB, and IP67 protection, this flowmeter is engineered to operate safely in potentially explosive or corrosive settings. The ATEX certification adds an extra layer of assurance, enabling use in rigorous process environments. Its robust construction and high-pressure capability allow for reliable long-term performance.

FAQs of Vortex Flowmeter:


Q: How does a Vortex Flowmeter measure flow in air, gas, and liquid applications?

A: This flowmeter utilizes the principle of vortex shedding, where fluid passing through a bluff body creates oscillations that are directly proportional to flow rate. By detecting these vortex pulses, the device accurately measures the velocity of air, gases, and liquids.

Q: What are the advantages of using a Vortex Flowmeter with ATEX and IP67 ratings?

A: ATEX certification ensures the flowmeter is safe for use in explosive atmospheres, while IP67 rating provides protection against dust and temporary immersion in water. Together, these standards make the flowmeter suitable for harsh industrial environments.

Q: When should I consider using a Vortex Flowmeter with a flange end connection?

A: A flange end connection is recommended for systems requiring secure, leak-proof fixation and easy maintenance. It is ideal for large-scale industrial setups, especially where regular inspection or servicing of the device is necessary.

Q: Where can this Vortex Flowmeter be installed for optimal performance?

A: It can be installed in pipelines measuring from 10 mm to 400 mm diameter, across industries such as chemical plants, refineries, water treatment facilities, and HVAC systems, provided the process conditions align with its specifications.

Q: What is the process for installing this flowmeter in my plant?

A: Installation involves aligning the flowmeter with the pipeline flanges, securing them with bolts, and connecting the instrument to the control system. Proper placement ensures accurate readings and conforms to safety standards.

Q: How does the high accuracy of 0.5% benefit my operations?

A: A 0.5% accuracy ensures precise flow measurement, which helps optimize process efficiency, ensure product quality, reduce wastage, and maintain regulatory compliance within industrial applications like those in India and abroad.

Unit of Price Piece/Pieces
Unit of Measure Piece/Pieces
Price 40000 INR
Function Air, Gas, Liquid flow measurement
Classification IIA, IIB, IP67, ATEX
Size 10 mm - 400 mm
Connection Flange end
Accuracy 0.5 %
Color Silver
Pressure 20 Bar
Supply Ability 50 Per Month
Delivery Time 4 Week
AUTOMAC Process Instrument & Valve Solution help you reduce cost ,and increase safety for your plant